2 Ton Induction Furnace Plant for Sale
Quantity of complete sets of equipment for induction furnace plant for sale: 1 set Configuration method of each set: one transformer, one set of independent intermediate frequency power supply system, two furnace bodies and accessories.
Application of induction melting electric furnace equipment: Mainly used for melting, heating, heat preservation, quenching, and tempering of cast steel, cast iron, ductile iron, etc.
Design and production requirements of 2 Ton Induction Furnace Plant for Sale
Working temperature: 1600℃
Rated capacity of each furnace body: 2t
The power of the intermediate frequency power supply system is adjustable, and the power adjustment range is 5-100%.
The main purpose 2 Ton Induction Furnace Plant for Sale is to enable users to improve productivity and meet different smelting needs, the heating section can be adjusted accurately, so that the furnace body can be smelted, kept warm, preheated, and sintered. One furnace body works and the other furnace body stands by. This can maximize production efficiency and reduce smelting costs.
An on-site operation cabinet is installed on the electric furnace platform to control the operation, stop, and power output adjustment of the power supply respectively, and the output power adjustment uses a large-diameter knob.
A set of independent intermediate frequency power supplies, and the configuration of two furnace bodies. When one furnace fails and needs to be repaired, the other furnace can work normally.
The system is equipped with a variety of protection functions and safe and reliable operation.
Our company installs a safety protection cabinet for the equipment, which can detect the water pressure and temperature of the power supply and each branch of the furnace body, as well as the furnace leakage alarm system of the furnace body, floor leakage alarm, etc.; hydraulic lock flow, system water pressure, water temperature Protective function.
The Main Technical Parameters of 2 Ton Induction Furnace Plant for Sale
A. Comprehensive parameters | |
Device form | Intermediate frequency melting furnace |
Equipment use | For cast iron, cast steel |
Rated Capacity | 2T |
Maximum capacity | 2t+10% |
Operating temperature | 1600°C (chemical steel) 1450°C (chemical iron) |
Hydraulic medium | Machinery oil |
Hydraulic station capacity | 500L |
Tilting method | Hydraulic control |
Tilting furnace maximum angle | 95 degrees |
Working noise | <85dB |
Furnace structure | Steel shell |
Outgoing way | Side outlet |
Power consumption/t | 630KW.H/T (steel—smelting state)560KW.H/T (iron—smelting state) |
Electrical parameters | |
Rated power | 1250KW |
Number of rectification phases | 12 pulses |
Inverter | SCR in parallel |
Rated frequency | 500Hz |
Incoming line voltage | 3×380V |
Inductor Voltage | 1400V |
Power startup success rate | 100% |
Power factor | 0.92 |
C. Cooling water system parameters | |
Inlet pressure | 0.2-0.4MPa |
Inlet water temperature | 5-35℃ |
Water temperature | <55℃ |
Cooling water flow | 38t/h |
Rectifier Transformer Technical Parameters
Specifications: ZPS-1500/6
Rated capacity: 10 Sc=1500kVA
Wiring method: D/Y
Primary rated voltage: U1=6kV or 10KV
Secondary side rated voltage: U2=380V×2
Connection group: D/Yn11~d0
Impedance voltage: Z75=7%
Cooling method: ONAN
Rectifier Transformer Use Conditions
(1) Altitude: +1000m
(2) Ambient temperature: 25-40°C
(3) The external protection measures of the transformer: heavy gas trip, light gas alarm, pressure relief valve protection and oil over-temperature alarm, on-load switch protection is consistent with the upper transformer.
Perfect Protection Technology of 2 Ton Induction Furnace Plant for Sale
Power protection measures include:
- Main circuit short circuit protection
- Main circuit phase loss protection
- High grid voltage protection
- Grid low voltage protection
- High cooling water temperature protection
- Cooling water low pressure protection
- Low cooling water flow protection
- Thyristor overvoltage protection
- Thyristor overcurrent protection
- Inverter thyristor current high rate of rise protection
- Insufficient commutation time protection of inverter thyristor
- Insufficient protection of inverter thyristor reverse turn-off voltage time